Encon Industrial Wastwater Evaporator

Industrial Wastewater Evaporators

The ENCON industrial wastewater evaporators range in capacity from 8-400 gal/hr evaporators. These evaporators are capable of being heated by waste oil, natural gas, #2 fuel oil, diesel, propane, steam, kerosene, or electricity. Alloys of construction include: 6% Molybdenum Super Stainless, 316L Stainless, and Hastelloy C to provide corrosion protection.

Click for Terminology View

The industrial evaporators are defined as referenced in the tables below.

For example, the ENCON wastewater evaporators model N3Y-60CUL is a Natural Gas, 316SS Wetted Material Construction, Auto-Fill (Y logic), 60 gallons per hour unit with a condenser and UL control panel. The available models, features and options are detailed below:

Evaporators Construction

3

- 316L Stainless Steel

6

- 6% Molybdenum (Super Stainless Alloy)

2

- Hastelloy C

Evaporators Heat

N

- Natural Gas

P

- Propane

O

- Oil, Kerosene, Diesel

W

- Waste Oil

E

- Electric

S

- Steam


encon

Evaporators Control Logic

Y (See Note 1) - Auto Fill, on-board level probe diagnostics and modem for remote dial-in. (Standard on 10 to 72 gal/hr evaporators)

Z (See Note 2) - Auto Fill, Auto-Dump, Auto Restart with Modem for remote dial-in. Also includes data archiving and on-board level probe diagnostics. (Standard on 96 to 400 gal/hr evaporators)

Note 1: Z Logic is available on the 10-72 gal/hr units.

Note 2: Auto-Dump option requires an additional residue pump, valve and level probe.


Evaporators Capacity

Drum Evaporator (Electric)

200 or 400 gallon per 5 day week

Electric Evaporator (gal/hr)

8, 15 & 24

Natural Gas, Propane, Oil & Steam Evaporator (gal/hr)

10, 18, 28, 35, 48, 60, 72, 96, 126, 165, 192, 260, 300 & 400


Option Codes

encon

Top View of ENCON Evaporators

 A

-  AutoDump

 C

-  Condenser

D

-  Auto-Decant

R

-  Remote Monitoring Panel

IR

-  IRI Gas Train

UL

-  UL Control Panel