Drum Evaporator/Dryer Process Description
(Click on each image to enlarge)


Drum Evaporator Batch Operation Step 1:

Drum Evaporation Batch Process Step 1Place a 55 gallon open top drum onto the drum dolly. Transfer wastewater into the drum to within 6-8 inches of the top. With the evaporator in the full open position, roll the drum into the evaporator.

Wrap the rope gasket around the drum so that a positive seal will be made when the clamshell walls are closed


Batch Operation Step 2:

Close the clamshell walls and secure the lid with latching handles.

Drum latching Handle

Exhaust ConnectionBatch Operation Step 3:

The evaporator stack is then connected to the flexible section of the permanent exhaust stack with a quick disconnect fitting.


Batch Operation Step 4:

Run the supply power to the top of the disconnect switch and through the bottom of the control panel enclosure.



Drum Evaporation Batch Process Step 5

Batch Operation Step 5:

With the main power on, allow the system to heat up to boiling temperature. The system will shutdown upon reaching the low level or high temperature set point which is factory set in your control panel.




Auto Fill Option:

The ENCON Drum Evaporator/Dryer can be modified to run in the auto-fill mode (optional high level probe required). This mode requires plumbing from a feed pump to the inlet on the top of the evaporator lid. This allows the automatic and continuous refilling of the evaporator between the height of the two level probes until either the high temperature set point is reached or there is no longer water to be processed in the holding tank (See Typical Drum Evaporator Installation).



Drum Evaporation Batch Process: Auto Fill Option